The HPE Smart Array P222 Controller is a low profile, 6 Gb/s, PCIe 3.0, Serial Attached SCSI (SAS) RAID controller that provides entry-level, storage performance, scalability, and data protection for select HP ProLiant Gen8 rack and tower servers. The HP Smart Array P222 controller is a low profile, 6 Gb/s, PCIe 3.0, Serial Attached SCSI (SAS) RAID controller that provides entry-level, second generation storage performance, scalability, and data protection for select HP ProLiant Gen8 rack servers and tower servers. I have an HP ProLiant DL180 G5 server with a Smart Array E200 RAID controller. The RAID controller is refusing to recognize inserted drives as an array. The story so far. This server (our file server) needed an upgrade. It started with 8 x 250GB drives: • 2 in RAID1 for the OS • 5 in RAID5 for data • 1 as a hot spare. The plan was to replace the RAID5 array and hot spare with a RAID10 array composed of much larger disks. Buy Powersuite and get SystemTweaker for FREE By resource. Product downloads. $59.95 Add to cart. Build 4.6.1.0. Download now. Cleverbridge AG is an authorized reseller of Uniblue's products. Click on below button to start Uniblue PowerSuite 2016 4.4.2.0 Free Download. This is complete offline installer and standalone setup for Uniblue PowerSuite 2016 4.4.2.0. This would be compatible with both 32 bit and 64 bit windows. Uniblue powersuite 2016 free download. Uniblue PowerSuite has made many efforts in the improvement of their latest software that is the Uniblue PowerSuite 2016. The Uniblue PowerSuite 2016 serial key has been recognized as the best tools for keeping maintenance of your PC and Maximizing the serial key speed of system. Get SystemTweaker for free when you buy Powersuite at our special download price of $59.95. For help on how to get started with Powersuite, download our easy to read quick start guide with a helpful overview to guide you through the application. Cleverbridge AG is an authorized reseller of Uniblue's products. Uniblue PowerSuite 2016 Crack Serial Key Free Download Uniblue PowerSuite 2016 Crack Overview! Uniblue PowerSuite 2016 Crack with Serial Key is the world’s most authenticated PC optimisation tool.It optimize performance and efficiency of hard disk drive, RAM including CPU. The old drives would be untouched in case any recovery was needed. The following process was used: • Shut down server • Remove drives used in data array and hot spare, and label with their positions. • Boot up the server and acknowledge errors about failed drives • Insert new drives and create new RAID10 array • Format new array and restore data from tape backup. This procedure worked as expected. But some data was missed in the last backup, so I need to recover data from the drives in the original array. ![]() ![]() Here's what I've done: • Shut down server • Remove drives used in new RAID10 array • Insert old drives according to position labels. • Boot up the server At this point, I get the following error: 1785-Slot 0 Drive Array Not Configured Drive positions appear to have changed. Run Array Diagnostics Utility (ADU) if previous positions are unknown. Then turn system power OFF and move drives to their original positions. I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case. I can hardly believe that the drives would be rendered inaccessible as soon as they are removed from the original RAID controller. Is there anything I can do to access the data on the old drives? If not, which RAID controllers support this, so I know what to buy in the future? I have already contacted HP support, and they were unable to help. Their recommendation was to recreate the RAID array and restore the data, but that doesn't really help my situation. The removed drives still have the RAID metadata on them. Smart Array P222 Controller FirmwareWhen you went to step #3 in the first drive replacement process; Boot up the server and acknowledge errors about failed drives, did you DELETE the removed array/logical drive or just mark it as failed? That's probably the source of the problem here. When you brought up the system with your old drives, you should have again deleted the new data logical drive either in the BIOS raid utility or with the Smartstart/DL180 Setup Array Configuration utility and let the controller detect the array/logical drive. Boot up with the new drives removed. Go into the BIOS or DL180 setup disk Array Config and delete the RAID 1+0 array. Then boot with your old drives and see if they're detected.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
January 2019
Categories |